SQL Client Lab is a read-only database inspection tool that uses the saved channels of an SQL Client module instance. Use it to check a connection, find tables and views, inspect their columns, and preview rows before configuring a transaction.
From N3uron version 1.22.8, the tool appears as SqlClient Lab below the SQL Client instance in the Explorer panel.
Lab reads the real database selected by the channel. Its operations do not insert, update or delete database rows, and they do not write values to N3uron Tags. Previewed values appear in the Result panel. They are not transferred to the Tag model.
The tool does not provide an SQL editor. Its Run button executes the selected inspection operation. The Run icon on a transaction's Pipeline header opens a separate script test window. See User-defined scripts for the script stages.
Open SQL Client Lab
Configure and save a database channel in your SQL Client instance. See Configuration for the connection settings.
In WebUI, open System > Config.
In the Explorer panel, expand Modules and the SQL Client module instance.
Select SqlClient Lab.
Select the saved Channel that you want to inspect.
The examples below use a running instance named SQL Client and its saved channel WindFarmSCADA. The selected channel supplies the database connection and credentials. You do not enter a password in SQL Client Lab.

Lab controls
Fields appear according to the selected operation. Set the visible fields, then press Run. After changing a field, press Run again to refresh the result.
Control | Description |
|---|---|
Channel | Selects a channel from the saved configuration of this SQL Client instance. Use the instance that owns the required database connection. |
Operation | Selects Test connection, List schemas and tables, Describe table or Preview rows. The initial operation is Test connection. |
Schema | Selects the database schema, a named group of tables and views. The field appears for listing, describing and previewing. Leave it empty to use the default schema. The PostgreSQL examples use public. |
Table | Names the table or view to inspect. This field is required for Describe table and Preview rows. In the example, enter turbine_telemetry and set Schema to public. |
Limit | Sets the maximum number of rows returned by Preview rows. Enter an integer from 1 to 500. The initial value is 50. This field does not appear for the other operations. |
Run | Executes the selected operation with the current Lab inputs. Lab initially shows Not run yet and waits for this action. This button does not save a transaction or apply the previewed values to Tags. |
Example: inspect wind-farm telemetry
The following example uses a PostgreSQL database for a wind farm. The database contains a view named turbine_telemetry, with one row for each of three wind turbines. A view presents query results as rows and columns.
Example item | Value |
|---|---|
Module instance | SQL Client |
Channel | WindFarmSCADA |
Database | wind_farm_scada |
Schema | public |
Table field | turbine_telemetry, a database view |
Database user | scada_sql_client |
Distinguish the database name from the schema name and the table or view name. In this example, wind_farm_scada is the database, public is the schema, and turbine_telemetry is the view. Use the corresponding names from your own database.
Check the connection
Select WindFarmSCADA in Channel.
Select Test connection in Operation.
Press Run and read the status below the button.
In this example, Connection OK and Online confirm a successful connection. The Result panel reports latency in milliseconds, the database product and version, the database user, server time, time zone and database. Read any warning alongside the successful status.

Note:
If the result reports SSL is disabled, review the channel's SSL configuration. That warning means that credentials and data travel without encryption. The example uses an isolated local database.
A successful connection check does not confirm permission to read every table or view. Test the required table or view with Preview rows.
Find tables and views
Select List schemas and tables.
Enter public in Schema, or leave Schema empty to use the default.
Press Run.
The Result panel lists the tables and views in the selected schema. In this example, it shows the turbine_assets table, the turbine_telemetry view, and two tables for turbine history. The log also lists the available schemas and identifies public as the default.
Result field | Meaning |
|---|---|
Schema | Schema that contains the table or view. |
Type | Shows whether the listed name refers to a table or view. |
Rows (estimate) | Estimated number of rows reported for the table or view. This is not an exact count. A blank estimate does not mean that there are no rows. |
Name | Name to use when selecting the table or view for the next operation. |
Describe a table or view
Select Describe table.
Set Schema to public.
Set Table to turbine_telemetry.
Press Run.
The example returns four columns: turbine_id, active_power_kw, wind_speed_ms and observed_at. Use this information to choose columns and data types when preparing a transaction.
Result field | Meaning |
|---|---|
Column | Column name in the inspected table or view. |
Native type | Column type reported by the database, such as double precision in this PostgreSQL example. |
Dataset type | Type used by SQL Client for the returned data, such as DOUBLE. A Dataset is a table of data used by SQL Client. |
Nullable | Shows whether the database reports that the column can contain NULL, which represents a missing value. |
Primary key | Indicates whether the column belongs to the reported primary key. A primary key uniquely identifies each row in a table. |
Auto increment | Indicates whether the database reports automatic increment for the column. |
Default | Default value or expression reported for the column. A blank cell means that no default is reported. |
The animation shows how to list the tables and views in public and inspect the columns of turbine_telemetry.

Preview row values
Select Preview rows.
Set Schema to public and Table to turbine_telemetry.
Set Limit to 2, then press Run.
Read the two returned rows. The message more rows follow indicates that the preview does not contain all available rows.
Change Limit to 50, then press Run again.
The second run returns all three rows in this example. The values include active power in kW, wind speed in m/s, and the observation timestamp. The Limit value caps the returned rows. It does not change the data in the database.
There is no next-page control in this preview. If the result reports more rows, increase Limit within its range and run the operation again. Use a transaction query when you need a specific filter, order or larger result.

Read the result and operation log
The status below Run reports success, the returned row or column count, or an error. The Result panel displays the response for the operation. The log below it shows Timestamp, Level and Message.
The following table summarizes messages obtained while using the example database. Read the complete message before changing the connection or the database permissions.
Message summary | Action |
|---|---|
Table is required for this operation | Enter a table or view name before running Describe table or Preview rows. |
Table does not exist or is not visible to the connection's user | Check the selected channel, Schema and Table. Also check whether the database user can see the table or view. This message alone does not identify which condition failed. |
DB_ERROR: permission denied for table turbine_assets | Ask the database administrator to review read access to that table. In the captured case, the database user could read turbine_telemetry but could not read the underlying turbine_assets table directly. |
The image below shows the actual permission error obtained before read access to the base table was granted. The connection check succeeded, and describing the table was possible. Reading its rows still required permission on that table.

Use Lab to inspect the connection and data. To read database values into N3uron Tags, configure a Standard transaction and its Parser. To store Tag events in the database, configure a History transaction. These configured transactions are separate from the Lab inspection operations.